Monday, March 28, 2011

Transformer Test Bench Exporters to UK, Germany, France, Italy

‘RE’ Electrical Test Bench for Testing Motors, transformers and electrical Equipment etc. The Test Panel shall be suitable for 3 phase input supply having 63 Amp MCB for each phase independently. Phase ON Indicator, Voltmeter with selector switch to indicate the voltage of each phase. Amperemeter with Multirange CT of 5/5, 5/15, 5/30 aand 5/60 A of class 0.5 accuracy for each phase, 3 Phase wattmeter of suitable range.


TECHNICAL SPECIFICATIONS

In addition following will be provided in the panel:
a)The Panel shall also consists of High current source having capacity 0-1000 amps. at 3 KVA. The Source shall be suitable for working on 230 V single phase 50 Hz. AC supply and complete with Output Bus-Bars and Input ON indicator etc. The Source shall have own Variable Transformer and shall be energise from one of the three phase supply.

b)AC HV Breaddown Tester shall be provided having capacity 0-5 KV at 100 mA and tripping at 5/25/50 and 100 mA. The unit shall be complete with test lead, input and output ON indicator.

c)0-24Volts at 10 Amps or 0-48 Volts at 5 Amps supply shall be provided brought out on Banana Terminals for testing DC Relay and other DC system etc. The unit shall be complete with ‘ON-OFF’ switch, input ‘ON’ indicator 72 sq.mm. output Voltmeter and Amperemeter.

d)A DC continuity tester shall also be provided with Indicator and ‘ON-OFF’switch.

e)Separate phantom loading arrangement shall be provided

f)Phase shifting arrangement shall be separately

g)All measuring instrument shall be of digital type.


For further details

Call us at: +91-11-41425851 / 52
E-mail us at: info@re-india.com

L.T. Parallel Inductor - AC High Current Test Set Suppliers Bangalore, Hyderabad, Cochin

Motorised moving coil and fixed reactor shall be provided for generating inductive current for canceling capacitive current to reduce the input current to 20% (from 750 A to 150 A)




For further details

Call us at: +91-11-41425851 / 52
E-mail us at: info@re-india.com

Secondary Current Injection Tester Manufacturers Suppliers Mumbai, Nagpur, Pune, Maharashtra

'RE' Secondary Injection Test Sets have been designed keeping in view the requirements of field and laboratory. The sets are portable, light in weight, yet having all the technical features for testing relays and contractors.

SPECIAL FEATURES
  • Compact Size.
  • Built in safety arrangements in case of short circuit and over loading.
  • Easy to operate.
  • Efficient after sales service.
  • Guaranteed for one year against manufacturing defects.



TECHNICAL SPECIFICATIONS

'RE' Portable Secondary Injection/Relay Test set is designed for working on 220/230 single phase 50Hz Ac supply and complete with power 'ON-OFF' indicator, circuit 'ON' indicator. The set will have following independent circuits depending upon functional requirement of customer. Each circuit shall have push button actuated, relay/contractor to control the output of the circuit. All these circuits and components shall be housed in Rigid PVC Suitcase with carrying handle or wheels in case of Higher capacity.

CURRENT CIRCUIT: To Inject current of desired value in the relay/contactor. This circuit consists of loading transformer, selector switch, variable control, fine adjustment. Depending upon specific requirement percentage selector switch can also be provided to inject current at various multiples. The current injected is indicated by Ampere Meter. For large range the Ammeter has a multiplier or current transformer.

VOLTAGE CONTROL: This circuit supplies voltage Independently as per requirement. The continuously variable voltage or fixed tap voltage can be provided as desired by the user. AC or DC or both voltages can be provided along with corresponding metering, indications, switches etc.

PHASE SHIFT CIRCUIT: This is incorporated only when special type of relays are to be tested. The phase angle between voltage & current is developed to obtain current operational parameters of the relay.

TIME CIRCUIT: Digital Timers with freezing facility is provided for recording the operation/tripping time of relays under test.

Each circuit is independent & push button operated, relay/contractor to control the output of the circuit.


For further details

Call us at: +91-11-41425851 / 52
E-mail us at: info@re-india.com

Friday, February 18, 2011

Primary Current Injection Tester - AC High Current

Primary Injection test sets are used to loading. Calibration and testing of CT's bimetals relays, Protection relays etc. Mostly Primary Injection Test set are designed as per customer's specification. The Primary Injections Test sets are of 15 minutes ON/30 Minutes OFF duty i.e. testing duty only. Loading transformers are design for continuous use for Temperature Rise for bus duct/Bus Bar etc. Optional accessories requirement may include cable termination, timer, Temperature Indicator, multiple contactor, individual Phase control etc.

SPECIAL FEATURES

  • Compact in nature
  • It is available in portable trolley type/stationery type model Amps.
  • Optional digital/analogue timer.
  • Main Transformer upto 25,000 Amps Naturally air cooled type.


TECHNICAL SPECIFICATIONS

STEP DOWN TRANSFORMER : A double wound transformer is used for supplying high current at low voltage for testing.
CURRENT CONTROL : A step less Auto Transformer is used for Controlling output current from Zero to Maximum.
INPUT VOLTAGE : 230/415 Volts single/two/three phase 50Hz. AC supply
OUTPUT VOLTAGE RANGES : As per requirement.
OUTPUT CURRENT : Upto 25000 Amps.
CAPACITY : Up to 500 KVA
DUTY : 15 Minutes ON-30 Minutes OFF in case of Primary Injection test set and continuous in case of Loading Transformer.
METERING : Multi range Ampere meter of class 1.5 with CT of class 0.5 are provided on secondary side to indicate output current.
PROTECTION : ON-OFF Switch with fuse is provided to protect the unit against short circuit, push button to actual and cut of output.
HOUSING : Each unit is housed in a MS sheet body, supported with angle iron frame. The oil cooled models are housed in suitable MS tank and the control panel is on the tank or as per requiems.
OPTIONAL : (a) Voltmeter (b) Timer as per requirement (c) Rubber cable (c) Zero start interlocking with by pass switch.
TERMINATION : The output is brought out on suitable Bus Bar/Terminals.


For further details

Call us at: +91-11-41425851 / 52
E-mail us at: info@re-india.com

Saturday, February 12, 2011

Variable Auto Transformers Manufacturers Exporters to UAE, Saudi Arabia, Oman, Yemen


Wherever voltage control is required, ‘RE’ Variacs makes it very simple by providing Toroidally wound Auto Transformer for variable voltage. If you have not yet used ‘RE’ Variacs you are missing some important benefits of using electric power. The maximum current that can be drawn depends on the size of the wire used. The ‘RE’ Voltage regulators are manufactured from 2 A to 2000 A for Single and Three Phase.

SPECIAL FEATURES

  • Compact in Size.
  • Easy to operate.
  • Special Insulating Paper is used for transformer winding.
  • Guaranteed for one year against manufacturing defects.
  • Efficient After Sales Service.


TECHNICAL SPECIFICATIONS

‘RE’ Variac Continuously Variable Auto Transformers usually form part of system in which other components such as transformers. Diode etc. are used as power components, ‘RE’ Variac Engineers are well experienced in such applications and are always available for consultation to prospective users.

The proportion between iron section and copper turns is such that at the maximum AC applied voltage maximum NO LOAD current is within 5%.

The insulation of the wire over one face is removed the output is taken between one end and the brush arm. The moving Brush contacts the next turn before it breaks away from the previous turn, thus, there is no interruption in output voltage.

‘RE’ Variac is designed to Boost the Output, Voltage by 12% than the input voltage. Three Single phase units are connected in star for 3 phase four wire system. The brush arms are moved by a common shaft and the Star point is connected to the neutral of the system. A three phase voltage variable from zero to 470V is obtained, if the Input voltage is 415V in case of single phase 270V is obtained if input is 240V. Custom made capacities can be manufactured and as yet the manufacturing range covers upto 2000 Amperes in three phase.

OPTIONAL: ‘RE’ Variacs are available with motor drive. The type of motor used for driving is specially made for this application. It is 240V AC motor operating with speed of 60 RPM synchronous at 50Hz. It is instantly reversible and can be stopped without overrun. It speed depends on frequency i.e. 60 RPM at 50 Hz. Supply. The desired speed is obtained by suitable by gearing. It starts stops & reverses instantly. It is ideal for automatic voltage control through Electronic system. *It can be stalled indefinitely without over heating.


For further details

Call us at: +91-11-41425851 / 52
E-mail us at: info@re-india.com